China Professional Waste Used Oil Refining Black Car Motor Lube Oil to Base Oil Distillation Manufacture vacuum pump electric

Product Description

 

Product Description

Waste Used Oil Refining Black Car Motor Lube Oil to base oil Distillation Manufacture can recycle pyrolysis oil,diesel motor oil,all kinds of engine oil,mineral oil,synthetic oil,and other waste lubricant oil.transmission oil,hydraulice oil,gear oil and other used black lubricant oil to clean oil.Cars,trucks,farm machines and ships all need regular lubricating oil changes.Motor oil picks up a variety of hazardous contaminants when used in engines and transmissions.These contaminants include lead,cadmium,chromium,arsenic,benzene and polycyclic aromatics.If used motor oil and the contaminants it contains are disposed of inappropriately and released into the environment,will has the potential to pollute land,water and infrastructure,so we need to recover and recycle as much as of it as possible .Our company made great efforts to find new technology in vacuum distillation plant,which can distill all kinds of waste oil into available oil with high recovery rate.

Oil comparison

Product Parameters

Model Data VBT-DB Waste Used Oil Refining Black Car Motor Lube Oil to base oil Distillation Manufacture
Working capacity 1-50 tons per day
Fuel consume ≥5 kg/h
Total Power consume ≥1*10^5 Kal/h
Fuel supply Light diesel fuels/Kerosenen/Heavy fuel oil/Environmental oil/Waste lube oil for burning(Molten salt CHINAMFG available)
Heating Method Natural gas/Gasoil/Coal/Power
power 5-55KW (The electric power (pump, control system, valves, etc.) required to burn the burner) or 18-522KW (Power required for electric heating)
Electricity consumption (20H) 360-10440
The waste oil of 1400 PPM sulfur content can be distilled with a desulfurizing agent and a catalyst to obtain a waste oil of 100-150 ppm sulfur content. The original cetane number is 45, after distillation, you can get cetane number of 51~55.

Flow chart

More details:

 

Our Advantages

Sales service

Pre-Sales Service

* We provide presales service in various forms, for example, making investment budget, manufacturing, so that the customers can make reasonable plan with less cost.
* Investment budgeting: we provided services of product profit analysis, recommendation of machine and relevant budgeting, human resources allocation and budgeting.
* Plant plHangZhou: we provide the dimension of the equipment base, design of the equipment layout, workshop construction suggestion etc.

After-Sales Service

* We provide customers free training so that they can use and maintain the machines independently.
* We will answer customers’ questions on technology in time. If needed, we will offer on-site guidance and assist.
* We will provide free technical guidance, if customers need new equipment, add or rebuild equipment.
* All the machines are life-long free technical assistant.
* All the machines are at most warranty 24 months for main parts. The consumable parts are 12 months.
 

/* March 10, 2571 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Certification: ISO9001, CE
Application: Turbine Oil, Lubricant Oil, Transformer Oil, Engine Oil, Black Waste Oil
Voltage: 380V
Customization:
Available

|

.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}

Shipping Cost:

Estimated freight per unit.







about shipping cost and estimated delivery time.
Payment Method:







 

Initial Payment



Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.

motor base

What are the key considerations when installing a motor base for optimal performance?

When installing a motor base for optimal performance, several key considerations should be taken into account. Here’s a detailed explanation:

1. Motor Base Selection: Choose a motor base that is compatible with the motor’s frame size and mounting requirements. Consider factors such as load capacity, structural integrity, vibration-dampening properties, and heat dissipation features. The base should provide a stable and secure platform for the motor.

2. Alignment: Ensure proper alignment between the motor and driven equipment. Misalignment can lead to increased friction, vibration, and premature wear. Use alignment tools and techniques to align the motor shaft and driven shaft accurately.

3. Leveling: Ensure the motor base is level to prevent unnecessary stress on the motor and its components. Use a spirit level or other leveling tools to adjust the base as needed.

4. Fastening: Securely fasten the motor base to the mounting surface using appropriate bolts, screws, or anchors. Follow the manufacturer’s recommendations for torque specifications to ensure proper tightening without overloading or damaging the base.

5. Vibration Isolation: Consider using vibration isolation pads or mounts between the motor base and the mounting surface to reduce vibrations and noise. These pads absorb and dampen vibrations, improving motor performance and reducing stress on the motor and surrounding equipment.

6. Clearance and Accessibility: Ensure adequate clearance around the motor base for maintenance and inspection activities. Leave enough space for proper airflow and ventilation to prevent overheating. Consider accessibility for routine maintenance tasks such as lubrication, belt adjustments, or motor inspections.

7. Environmental Factors: Consider the environmental conditions in which the motor will operate. Protect the motor base from moisture, dust, extreme temperatures, or corrosive substances that could affect its performance. Install appropriate protective enclosures or covers if necessary.

8. Documentation and Labeling: Keep detailed documentation of the motor base installation, including drawings, schematics, and torque specifications. Label the motor base with relevant information such as motor identification, installation date, and maintenance requirements.

9. Periodic Inspection and Maintenance: Regularly inspect the motor base for signs of wear, damage, or misalignment. Perform routine maintenance tasks such as lubrication, cleaning, and tightening of fasteners as recommended by the manufacturer.

10. Compliance with Regulations: Ensure compliance with local regulations, safety standards, and electrical codes when installing the motor base. Adhere to proper grounding and electrical connection practices to ensure safety and compliance.

By considering these key factors during motor base installation, you can optimize motor performance, reliability, and efficiency. A well-installed motor base provides a stable mounting platform, proper alignment, vibration reduction, and easy access for maintenance, contributing to the overall performance and longevity of the motor.

motor base

Can motor bases be used with both AC and DC electric motors?

Yes, motor bases can generally be used with both AC (alternating current) and DC (direct current) electric motors. Here’s a detailed explanation:

1. Universal Compatibility: Motor bases are typically designed to accommodate a wide range of motor types and sizes. They are engineered to provide a universal mounting interface that can support various motor configurations, including both AC and DC motors. This allows for flexibility and ease of installation regardless of the motor type.

2. Standardized Mounting Patterns: Motor bases often adhere to standardized mounting patterns, such as those defined by organizations like the National Electrical Manufacturers Association (NEMA) or the International Electrotechnical Commission (IEC). These standards specify the dimensions and hole patterns for motor mounting, ensuring compatibility with different motor types, including AC and DC motors.

3. Adjustability: Many motor bases feature adjustable mounting slots or bolt-hole patterns. This adjustability allows for fine-tuning the motor’s position and alignment during installation, regardless of whether it’s an AC or DC motor. Adjustability is especially important for achieving optimal alignment, which is crucial for motor performance and efficiency.

4. Mechanical Stability and Support: Motor bases provide mechanical stability and support to electric motors, regardless of their power source. They help secure the motor in place and prevent excessive vibration, ensuring reliable and efficient operation. The structural integrity and load-bearing capacity of motor bases are designed to handle the requirements of both AC and DC motors.

5. Application-Specific Considerations: While motor bases can generally be used with both AC and DC motors, it’s important to consider specific application requirements. AC and DC motors may have different operational characteristics, such as starting current, torque characteristics, or speed control methods. These differences may influence the selection of a motor base, particularly if the application demands specialized features or adjustments to accommodate the specific motor type.

When selecting a motor base for use with AC or DC motors, it’s advisable to consult the motor manufacturer’s recommendations and specifications. Additionally, consider any application-specific factors that may influence the choice of motor base, such as environmental conditions, load requirements, or vibration considerations.

By ensuring compatibility and proper installation, motor bases can effectively support and enhance the performance of both AC and DC electric motors across a wide range of applications.

motor base

What materials are commonly used in the construction of durable motor bases?

Durable motor bases are constructed using various materials that provide strength, stability, and longevity. Here’s a detailed explanation:

Motor bases are designed to withstand the weight and operational forces of electric motors while maintaining stability and alignment. The choice of materials for motor base construction depends on factors such as the motor size, application requirements, and environmental conditions. Here are some commonly used materials:

1. Steel: Steel is one of the most commonly used materials for motor bases due to its exceptional strength and durability. Motor bases made of steel can withstand heavy loads and resist deformation. Steel motor bases are known for their rigidity, stability, and ability to dampen vibrations. They are suitable for a wide range of motor sizes and industrial applications.

2. Cast Iron: Cast iron is another popular material for motor bases, especially for larger motor sizes. Cast iron offers excellent stability and resistance to deformation under heavy loads. It has high compressive strength and can effectively absorb and dampen vibrations generated during motor operation. Cast iron motor bases are known for their long-lasting performance and suitability for demanding industrial environments.

3. Aluminum: Aluminum motor bases are commonly used for smaller or lighter motor applications. Aluminum is lightweight, corrosion-resistant, and offers good thermal conductivity. Motor bases made of aluminum are easy to handle and install. They are often preferred in applications where weight reduction is desired, such as in portable or mobile equipment.

4. Composite Materials: In some cases, motor bases may be constructed using composite materials such as fiberglass-reinforced plastic (FRP). Composite motor bases offer a combination of strength, lightweight construction, and corrosion resistance. They are particularly suitable for applications where weight reduction, electrical insulation, or resistance to chemicals and corrosive environments are important considerations.

5. Other Materials: Depending on specific requirements, motor bases can also be constructed using other materials such as stainless steel, galvanized steel, or specialized alloys. These materials may be chosen for their specific properties, such as resistance to corrosion, high-temperature applications, or compatibility with certain environmental conditions.

When selecting a motor base material, it’s essential to consider factors such as load capacity, environmental conditions (such as exposure to moisture, chemicals, or extreme temperatures), and the specific needs of the application.

In summary, durable motor bases are commonly constructed using materials such as steel, cast iron, aluminum, composite materials, and other specialized alloys. Each material offers specific advantages in terms of strength, stability, weight, corrosion resistance, and other properties, allowing motor bases to withstand the demands of industrial applications.

China Professional Waste Used Oil Refining Black Car Motor Lube Oil to Base Oil Distillation Manufacture   vacuum pump electricChina Professional Waste Used Oil Refining Black Car Motor Lube Oil to Base Oil Distillation Manufacture   vacuum pump electric
editor by CX 2024-02-04

motor base

As one of leading motor base manufacturers, suppliers and exporters of mechanical products, We offer motor base and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of motor base

Recent Posts