China supplier New Style Multiple Dual Motors Automatic Height Adjustable Table Frames Adjustable Height Desk Base vacuum pump electric

Product Description

The feature of electric office desk is the adjustable height of the desktop.
According to the request of the user in the actual using, the office desk can be adjusted into different height.
It has the location memory to the prefer location which the user are used to. If the height is adjusted by other user,
You just need to press 1 memory button and then the height will be back to the original one.
It is very convenient and saves time for the user.

1. Input voltage: 110V/220V AC 50/60Hz;
2. Output voltage: 24V DC;
3. The stroke: 500mm ();
4. Max load capacity: 2000N;
5. No load speed: 23mm/s;
6. Type of duty: 10%.

Model No.: FYED-2-490-670-1000-H-W-2
Input voltage 100-240VAC
Output voltage 24VDC
Load capacity 1000N

1. Button “UP1” and Button “DN1” are to control the lifting up and down of the office desk(self lock). Pressing button up1 and loose the finger, the office desk will lift up automatically. Pressing button DN1 at 1 time and loose the finger, the office desk will lift down automatically. It will stop when you press 1 of the button “UP1”, “UP2”, “DN1”, “DN2” in the process of automatically lifting up or down. (as pic 2)
2. Button “UP2”, “DN2” are to control the office desk up and down. Pressing button UP2, the desk will lift up and it will stop when you loose the finger. Pressing button DN2, the desk will lift down and will stop when you loose the finger. (as pic 2). (DN2 has the reset function too at the same time).
3. Reset button DN2 is used when the synchronous work of the office desk has the bigger accumulative tolerance and work abnormally. Pressing DN2 and not moving the finger, the desk will lift down all the time to the bottom. And then do not move your finger and keep pressing for 5 seconds, the office desk will have the rebound action which is up 5mm. It is a successful reset.
4. Memory button S need to work together with location key 1, 2, 3, 4. Firstly you need to set the memory location, for example when the desk lift up to 100mm location, you
Should press Key S and location button 1 at the same time. When the desk lift up to 200mm, press key S and button 2 at the same time. When the desk lift up to 300mm, press S and 3 at the same time. When the desk lift up to 400mm, press S and 4 at the same time. When we set well the location memory, we could use them. For example, when the desk is at any location, press button 1, the desk will be back to 100mm location. Press button 3, it is back to 300mm.
5. Digital display. When the desk lift up and down, the digital display will show the detail location and some code when the desk is in some special situation.
6. Used protection. When the desk work 3 minutes continuously, it will stop work automatically, and back to normal state after 999 seconds. Digital display will show “hot” code and count down 999 seconds.
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Style: Modern
Material: Metal
Wood Style: Panel
Condition: New
Input Voltage: 110V-220VAC
Output Voltage: DC24V
Samples:
US$ 1/Piece
1 Piece(Min.Order)

|

Customization:
Available

|

motor base

How do motor bases contribute to ease of maintenance for electric motors?

Motor bases play a significant role in facilitating ease of maintenance for electric motors. Here’s a detailed explanation:

1. Accessibility: Motor bases provide easy access to the motor for maintenance purposes. They offer a stable and secure platform that allows technicians to reach the motor quickly and perform routine tasks such as inspection, cleaning, lubrication, and belt adjustments. Motor bases with open designs or removable covers further enhance accessibility by providing unobstructed access to critical motor components.

2. Adjustability: Many motor bases are adjustable, allowing for precise positioning and alignment of the motor. This adjustability simplifies maintenance procedures as it enables technicians to align the motor shaft with the driven equipment accurately. Proper alignment helps reduce wear, vibration, and energy loss, ultimately improving the motor’s performance and extending its lifespan.

3. Vibration Reduction: Motor bases often incorporate features that help dampen vibrations generated by the motor. Excessive vibrations can lead to premature wear and damage to both the motor and surrounding equipment. Motor bases equipped with vibration isolation pads or mounts absorb and dissipate vibrations, reducing stress on the motor and minimizing the need for frequent maintenance or repairs.

4. Easy Removal and Replacement: In some situations, it may be necessary to remove the motor from its base for more extensive maintenance or repairs. Motor bases are designed to facilitate the removal and replacement of motors as needed. They typically provide mounting features that allow for straightforward disconnection and reconnection of the motor, saving time and effort during maintenance activities.

5. Documentation and Labeling: Motor bases often include labeling or documentation areas where relevant information can be recorded. This documentation can include motor identification details, installation dates, maintenance schedules, and torque specifications. Having this information readily available on the motor base simplifies maintenance planning, tracking, and troubleshooting.

6. Compatibility with Accessories: Motor bases are often designed to be compatible with various accessories that aid in maintenance. These accessories may include cable management systems, drip pans for fluid containment, or mounting brackets for additional components. The compatibility of the motor base with such accessories enhances ease of maintenance by providing integrated solutions that support efficient and organized maintenance practices.

By incorporating these features and considerations, motor bases contribute to the ease of maintenance for electric motors. They provide accessibility, adjustability, vibration reduction, and easy removal options, simplifying routine maintenance tasks and ensuring the smooth operation and longevity of electric motors.

motor base

How can users troubleshoot common issues related to motor base misalignment?

Troubleshooting common issues related to motor base misalignment can help ensure optimal performance and prevent potential problems. Here’s a detailed explanation:

1. Visual Inspection: Start by visually inspecting the motor base and its alignment with the driven equipment. Look for any obvious signs of misalignment, such as gaps, uneven contact, or skewed positioning. Pay attention to the alignment of coupling or drive belts, as they can indicate misalignment issues as well.

2. Measurements and Alignment Tools: Use precision measurement tools such as dial indicators, laser alignment devices, or straightedges to assess the alignment of the motor base. These tools can provide accurate measurements and help identify misalignment issues. Measure the alignment at multiple points along the motor base and compare the readings to the manufacturer’s recommended tolerances.

3. Check Mounting Bolts and Fasteners: Loose or improperly tightened mounting bolts and fasteners can contribute to motor base misalignment. Ensure that all bolts and fasteners are securely tightened according to the manufacturer’s specifications. If any bolts are found to be loose, tighten them appropriately. However, be cautious not to overtighten, as it can lead to deformation or misalignment of the motor base.

4. Assess Foundation or Mounting Surface: Examine the foundation or mounting surface on which the motor base is installed. Uneven or unstable surfaces can cause misalignment. Check for any irregularities, such as cracks, gaps, or soft spots, that may affect the alignment of the motor base. If necessary, repair or reinforce the foundation to ensure a stable and level mounting surface.

5. Alignment Adjustment: If misalignment is detected, make the necessary adjustments to bring the motor base into proper alignment. This may involve loosening the mounting bolts, adjusting shims or wedges, and repositioning the motor base. Follow the manufacturer’s guidelines or consult alignment experts for specific adjustment procedures based on the type of motor base and alignment method used.

6. Consider Thermal Growth: Account for thermal growth when aligning the motor base. Motors can experience thermal expansion or contraction during operation, which can affect alignment. Consult the manufacturer’s recommendations for thermal growth allowances and adjust the alignment accordingly.

7. Regular Maintenance: Implement a regular maintenance program that includes periodic inspections and realignment of the motor base. Over time, environmental factors, operational stresses, or equipment vibrations can cause misalignment. Regular maintenance helps identify and address misalignment issues before they escalate and lead to more severe problems.

8. Professional Assistance: If troubleshooting and adjustments do not resolve the misalignment issues, or if the alignment task requires specialized knowledge and equipment, seek assistance from alignment professionals or qualified technicians. They have the expertise and tools to accurately diagnose and correct complex misalignment problems.

It’s important to note that proper alignment of the motor base is essential for the smooth and efficient operation of the entire system. Misalignment can result in increased wear and tear, reduced energy efficiency, excessive vibration, premature component failure, and decreased overall performance. By promptly addressing misalignment issues, users can optimize the performance and lifespan of their motor base and associated equipment.

motor base

Are there different types of motor bases available for various motor sizes?

Yes, there are different types of motor bases available to accommodate various motor sizes in industrial applications. Here’s a detailed explanation:

Motor bases are designed to provide a secure and stable mounting platform for electric motors. Since motors come in different sizes and configurations, motor bases are available in various types to accommodate these variations. Here are some common types of motor bases:

1. Adjustable Motor Bases: These motor bases feature adjustable mounting slots or bolt patterns that allow for flexibility in positioning the motor. They are designed to accommodate a range of motor sizes within a specified range, making them versatile for different motor sizes. Adjustable motor bases are convenient when the motor size may vary or change over time.

2. Fixed Motor Bases: Fixed motor bases, also known as rigid motor bases, are designed for specific motor sizes. They have pre-drilled holes or specific mounting patterns that match the dimensions of a particular motor size. These bases provide a precise fit and ensure stable mounting for the designated motor size.

3. Slide Bases: Slide bases, also called sliding motor bases or motor slide rails, are used when motor adjustment or repositioning is necessary. They allow for horizontal movement or sliding of the motor to adjust the belt tension or align pulleys. Slide bases are commonly used in belt-driven systems where proper alignment and tensioning are critical.

4. Spring-Isolated Motor Bases: Spring-isolated motor bases are designed to minimize vibrations and dampen shock transmission from the motor to the supporting structure. These bases incorporate springs or elastomeric elements that isolate the motor from the mounting surface, reducing the potential impact of vibrations on the surrounding equipment or structure. Spring-isolated motor bases are commonly used in applications where vibration control is crucial, such as in sensitive electronic or precision machinery.

5. Custom Motor Bases: In certain cases, custom motor bases may be required to meet specific installation requirements or environmental conditions. Custom motor bases can be designed and fabricated to accommodate unique motor sizes, shapes, or mounting configurations. These bases are tailored to the specific needs of the application, ensuring proper fit and functionality.

Motor bases are typically made of sturdy materials like steel or cast iron to provide strength and durability. When selecting a motor base, it’s important to consider the motor size, weight, mounting requirements, and the specific needs of the application.

In summary, there are different types of motor bases available to accommodate various motor sizes. Adjustable motor bases, fixed motor bases, slide bases, spring-isolated motor bases, and custom motor bases offer different features and benefits depending on the specific motor size and installation requirements.

China supplier New Style Multiple Dual Motors Automatic Height Adjustable Table Frames Adjustable Height Desk Base   vacuum pump electricChina supplier New Style Multiple Dual Motors Automatic Height Adjustable Table Frames Adjustable Height Desk Base   vacuum pump electric
editor by CX 2024-03-15

motor base

As one of leading motor base manufacturers, suppliers and exporters of mechanical products, We offer motor base and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of motor base

Recent Posts